Home Vacuum Components Sample Holders

Sample Holders PDF

The sample holders are one of the most critical part of the surface measurement in UHV systems. The more dedicated the sample holder is, the better the measurement results. The results of the whole experiment can sometimes depend on the idea, design, materials and precision of the holders.


In PREVAC we invest a lot of time and experiments in sample holders development. Our standard in sample holders is called PTS and this exists in our complete range of systems. However, we design and develop all holders according to the customer’s wishes and needs. We are also very open to all sample holders adaptation, especially if we combine various kinds of holders standards in one UHV system. If it is necessary we can offer our help in development and improvement of the new holders.

The PTS STANDARD sample holder for easy sample mounting and optional BIAS current measurement.

The PTS POWDER SAMPLE HOLDER is designed for powder samples that do not require heating or cooling.
The PTS BASE CONTAINER SAMPLE HOLDER is designed as an adapter to accept samples up to 50mm diameter and 7.5mm thick.
The PTS 1000 RES/C-K sample holder has indirect (resistive) sample heating up to 1000°C and cooling to –170°C.
PTS 1000 RES/C-K sample holder with extra contacts is specifically for use in the MBE Chamber.
The PTS 1200 EB/C-K Mo sample holder features electron beam sample heating up to 1200°C, and cooling to –180°C.
The PTS 2000 EB/C-C sample holder features electron beam sample heating up to 2000°C.
The PTS with Direct Heating holder allows direct heating of the sample up to 1200°C and cooling down to -170°C.
The PTS HPC RES/C-K RG sample holder is dedicated for the High Pressure Cell (reactor).
The PTS HPC RES/C-K RG Sample Holder is for high pressure, reactive gas studies of powdered catalyst samples.
The PTS CLEAV RES/C-K is specifically designed for sample cleaving.
The PTS CLEAV Sample Holder is a version of the PTS CLEAV RES/C-K holder without heating or cooling capabilities.
The PTS 1000 IR RES/C-K Sample Holder is designed specifically for optical transmission spectroscopy (IR, UV) over the temperature range –170°C to 1000°C.
The PTS 1000 OMC RES/C-K sample holder adapts to Omicron sample holders for systems that are equipped with an Omicron STM.
The PTS 1400 OMC EB/C-K sample holder adapts to Omicron sample holders.
The PTS 1200 RHK EB/C-K sample holder has indirect sample heating up to 1200°C and cooling down to –170°C.
The PTS SPM DIR/C-K Sample Holder is for SPM work and is equipped with direct sample heating and cooling over the range -170°C to 1200°C.
The PTS SPM Cleav sample holder combines sample cleaving capabilities with SPM compatibility over the temperature range -170°C to 1200°C (indirectly heated).
The PTS SPM 2000 EB/C-C sample holder is for SPM work and is equipped with direct sample heating and cooling over the range -170°C to 2000°C.
The PTS QUARTZ sample holder is equipped with integrated quartz balance for deposition rate measurements.
The PTS FARA sample holder has integrated Faraday Cup with secondary electron suppressor for beam profile measurements.
The PTS Faraday Cup with extra capability Sample Holder has replaceable aperture plates.
Mini PTS sample holder designed for closed cycle cryostat.
The PTS 200 RES sample holder features a heated, rotating wire of 129mm L and 0.5mm dia (max) for vapor deposition experiments.

 

Click here for Sample Holder catalog.

 