Analytical systems

Ultra High Resolution Photoemission Spectrometer [project 351]

A analytical UHV system dedicated for investigation of the chemical and physical properties of solid state surfaces in low temperatures and UHV conditions.

Transferring system:

Mini PTS Sample holder.

System configuration:

- Analysis chamber with base pressure range 5*10-11 mbar include:

  • Close cycle 5-axis high resolution manipulator with LHe cooling (temperature on the sample down to 13K) – full motorized
  • High performance electron analyzer XPS/UPS/ARPES
  • Monochromatic X-ray source for XPS measurement
  • Monochromatic UV source with dedicated pumping system for UPS measurement.
  • Additional free port for other components

 

- Load Lock chamber allows loading up to 5 miniPTS sample holder

- Two-level Preparation chamber equipped with:

  • High precision 4-axis manipulator with LN2 cooling and EB heating up to 1200°C
  • Ion sputter source for sample cleaning
  • Deposition rate measurement system: Quartz Balance and Thickness monitor
  • Electron Beam Evaporator
  • LEED for Leed /Auger measurement
  • Additional free ports for other components in future

- Storage Chamber including park mechanism for six miniPTS sample holders

- Radial distribution chamber (UFO) for transferring the samples are transferred between chambers under UHV pressures

- Accessories:

  • Set of dedicated, multifunctional, multimaterial sample holders
  • Special rack for all electronics unit
  • Special design bakeout system
  • Chiller
  • Tool kits

Related products

» Systems

UHV system [project 063]

» UHV system [project 063]

Ultra high vacuum system for investigation of surface conditions of samples under controlled conditions.

read more
Custom UHV system for OLED research [project 014]

» Custom UHV system for OLED research [project 014]

A custom multichamber UHV system for the preparation and investigation of organic films (OLEDs).

read more
PLD system [project 198]

» PLD system [project 198]

UHV cluster with PLD chamber and mobile preparation chamber.

read more
HIPIMS system [project 335]

» HIPIMS system [project 335]

The HIPIMS Reactor is a dual purpose deposition chamber. It allows accurate and reproducible thin film layer deposition and extensive plasma diagnostic investigation.

read more
See more  ›

» Components

Storage Chamber

» Storage Chamber

The storage chambers allow storage of up to 10 sample holders under UHV conditions.

read more
Mirror/Gratings System Manipulators

» Mirror/Gratings System Manipulators

Multi-axis manipulator in order to determine the correct direction of the beam.

read more
Quartz Balance QO 40A1

» Quartz Balance QO 40A1

The Quartz Balance QO 40A1 provides a real-time, progressive indication of coating thickness during deposition, for high accuracy and reproducibility in coatings production.

 
read more
Wobble Sticks with Cleaver

» Wobble Sticks with Cleaver

3-axis manipulator dedicated to cut the sample in UHV chambers.

read more
See more  ›

» Electronics

Research Unit Digital Instrument RUDI-8M

» Research Unit Digital Instrument RUDI-8M

Modular, compact high voltage power supply for e.g. photoemission applications.

read more
X-ray High Voltage Power Supply XRHV01-PS

» X-ray High Voltage Power Supply XRHV01-PS

High voltage power supply for X-ray source RS 40B1.

read more
X-ray Cooling Controller XRCB-02

» X-ray Cooling Controller XRCB-02

The XRCB-02 Cooling Controller is mainly used to cooling control of the X-ray sources.

read more
X-ray Source Electronics Set XREC20

» X-ray Source Electronics Set XREC20

XREC20 electronics set dedicated for controlling SAX X-ray sources.

read more
See more  ›

» Software

Spectrium

» Spectrium

Control and data acquisition software dedicated to EA15 class analysers.

read more
Synthesium

» Synthesium

New software dedicated to vacuum deposition applications.

read more
Application for Thermal Desorption Spectroscopy

» Application for Thermal Desorption Spectroscopy

Used to control the power, preparing a recipe for heating and acquisition of measured data.

read more
See more  ›

TOP
Newsletter

Important:
this site uses cookie files.

We use information saved in cookie files, among others, in statistical purposes and in order to fit the service to individual needs of the user. In your browser you can change your cookie files settings.

Using the site without changing cookie files settings means they will be saved in device memory. More information with tips how to change settings can be found in Privacy policy.

Close

Query list

Ask