Others

System for investigation of interfacial phenomena of liquid metals in the contact with solids [project 052]

Description

System designed for studies of thermodynamics and kinetics of phase transformation:

  • Investigation of factors affecting stability and reactivi­ty of materials in different environments
  • Studies of high temperature liquid state phenomena (wettability, spreading, infiltration, interfacial reaction)
  • Measurements of contact angle, surface tension and density of molten materials at 20-2000°C under vacuum or protective atmosphere using a sessile drop method
  • Determination of thermal expansion/shrinkage of li­quid and semi-liquid materials during heating/cooling

 

Specification

The system is characterised by the following features:

  • Vacuum chamber for first stage sample preparation by preheating in vacuum up to 200°C in order to remo­ve adsorbed gases
  • Distribution chamber for sample transfer equipped with dedicated manipulator for samples of different size and various shape
  • Auger spectroscopy for surface characterisation of examined materials before and after high temperature studies or special treatment
  • Experimental chamber for high temperature studies of materials in solid, semi-solid or molten states, containing an experimental table with rotation and vertical movement, heater and moveable screens and  additional windows for observation and recording
  • Storage chamber
  • Residual gas analyser

 

System capabilities:

  • Classical sessile drop method, improved sessile drop method (dispensed drop, capillary purification techni­que)
  • Transferred drop (sandwich method, double plates me­thod)
  • Pendant drop
  • Maximum temperature 2000°C
  • Vacuum up to 10-7 hPa or protective atmosphere
  • Flowing gas with controlled rate at required level of pressure inside vacuum chamber
  • Controlled heating of examined paired materials
  • Independent loading system
  • Automatic real-time control of chemical composition of atmosphere during tests
  • Automatic real-time control of temperatureControl of chemical surface of examined samples be­fore, during and after tests

Related products

» Components

Analytical Chambers

» Analytical Chambers

Analytical chambers are designed for applications requiring the investigation of the chemical and physical properties of solid state surfaces, thin films and nanomaterials.

read more
Load Lock Chambers

» Load Lock Chambers

Load lock chambers provide a fast and clean method of introducing samples into UHV systems.

read more
Preparation Chambers

» Preparation Chambers

Preparation chambers provide versatile in-situ preparation facilities ranging from standard sample preparation techniques and thin film growth, sputtering and annealing, to advanced preparation techniques with in-situ characterisation.

read more
Radial Distribution Chambers (UFO)

» Radial Distribution Chambers (UFO)

The radial distribution chambers (UFO) are designed to transfer samples between multiple preparation and analysis chambers that are connected to it.

read more
Special Chambers

» Special Chambers

Custom designed and fabricated UHV chambers and complete vacuum systems for a wide range of applications, including research/production prototype MBE, Pulsed Laser Deposition, PVD magnetron sputtering & atomic and molecular physics/chemistry.

read more
PTS STANDARD sample holder

» PTS STANDARD sample holder

The PTS STANDARD sample holder for easy sample mounting and optional BIAS current measurement.

read more
PTS POWDER sample holder

» PTS POWDER sample holder

The PTS POWDER SAMPLE HOLDER is designed for powder samples that do not require heating or cooling.

read more
PTS BASE CONTAINER sample holder

» PTS BASE CONTAINER sample holder

The PTS BASE CONTAINER SAMPLE HOLDER is designed as an adapter to accept samples up to 50mm diameter and 7.5mm thick.

read more
PTS 1000 RES/C-K sample holder

» PTS 1000 RES/C-K sample holder

The PTS 1000 RES/C-K sample holder has indirect (resistive) sample heating up to 1000°C and cooling to –170°C.

read more
PTS 1000 RES/C WITH EXTRA CONTACT sample holder

» PTS 1000 RES/C WITH EXTRA CONTACT sample holder

PTS 1000 RES/C-K sample holder with extra contacts is specifically for use in the MBE Chamber.

read more
PTS 1200 EB/C-K Mo sample holder

» PTS 1200 EB/C-K Mo sample holder

The PTS 1200 EB/C-K Mo sample holder features electron beam sample heating up to 1200°C, and cooling to –180°C.

read more
PTS 2000 EB/C-C sample holder

» PTS 2000 EB/C-C sample holder

The PTS 2000 EB/C-C sample holder features electron beam sample heating up to 2000°C and is designed specifically for high temperature experiments.

read more
PTS 1200 DIR/C-K sample holder

» PTS 1200 DIR/C-K sample holder

The PTS with Direct Heating holder allows direct heating of the sample up to 1200°C and cooling down to -170°C.

read more
PTS 700/-90 HPC RES/C-K RG sample holder

» PTS 700/-90 HPC RES/C-K RG sample holder

The PTS HPC RES/C-K RG sample holder is dedicated for the High Pressure Cell (reactor).

read more
PTS 700/-90 HPC RES/C-K RG PS sample holder

» PTS 700/-90 HPC RES/C-K RG PS sample holder

The PTS HPC RES/C-K RG Sample Holder is for high pressure, reactive gas studies of powdered catalyst samples.

read more
PTS CLEAV RES/C-K sample holder

» PTS CLEAV RES/C-K sample holder

The PTS CLEAV RES/C-K is specifically designed for sample cleaving.

read more
PTS CLEAV sample holder

» PTS CLEAV sample holder

The PTS CLEAV Sample Holder is a version of the PTS CLEAV RES/C-K holder without heating or cooling capabilities.

read more
PTS 1000 IR RES/C-K sample holder

» PTS 1000 IR RES/C-K sample holder

The PTS 1000 IR RES/C-K Sample Holder is designed specifically for optical transmission spectroscopy (IR, UV) over the temperature range –170°C to 1000°C.

read more
PTS 1000 OMC RES/C-K sample holder

» PTS 1000 OMC RES/C-K sample holder

The PTS 1000 OMC RES/C-K sample holder adapts to flag style sample holders for systems that are equipped with STM.

read more
PTS 1400 OMC EB/C-K sample holder

» PTS 1400 OMC EB/C-K sample holder

The PTS 1400 OMC EB/C-K sample holder adapts to flag style sample holders for systems that are equipped with STM.

read more
PTS 1200 RHK EB/C-K sample holder

» PTS 1200 RHK EB/C-K sample holder

The PTS 1200 RHK EB/C-K sample holder has indirect sample heating up to 1200°C and cooling down to –170°C.

read more
PTS SPM DIR/C-K sample holder

» PTS SPM DIR/C-K sample holder

The PTS SPM DIR/C-K Sample Holder is for SPM work and is equipped with direct sample heating and cooling over the range -170°C to 1200°C.

read more
PTS SPM CLEAV sample holder

» PTS SPM CLEAV sample holder

The PTS SPM Cleav sample holder combines sample cleaving capabilities with SPM compatibility over the temperature range -170°C to 600°C (indirectly heated).

read more
PTS SPM 2000 EB/C-C sample holder

» PTS SPM 2000 EB/C-C sample holder

The PTS SPM 2000 EB/C-C sample holder is for SPM work and is equipped with electron beam sample heating up to 2000°C.

read more
PTS QUARTZ sample holder

» PTS QUARTZ sample holder

The PTS QUARTZ sample holder is equipped with integrated quartz balance for deposition rate measurements.

read more
PTS FARA sample holder

» PTS FARA sample holder

The PTS FARA sample holder has integrated Faraday Cup with secondary electron suppressor for beam profile measurements.

read more
PTS FARA EXTRA CAPABILITY sample holder

» PTS FARA EXTRA CAPABILITY sample holder

The PTS Faraday Cup with extra capability Sample Holder has replaceable aperture plates.

read more
MINI PTS sample holder

» MINI PTS sample holder

Mini PTS sample holder designed for closed cycle cryostat.

read more
PTS 200 RES sample holder

» PTS 200 RES sample holder

The PTS 200 RES sample holder features a heated, rotating wire of 129mm L and 0.5mm dia (max) for vapor deposition experiments.

read more
Flag style sample holders

» Flag style sample holders

Commonly used sample holder for a wide range of applications.

read more
Deposition holders

» Deposition holders

Sample holders (substrate holders, plates, wafers, molyblocs) dedicated for different deposition techniques, such as MBE, magnetron sputtering, thermal evaporation and others.

read more

» Electronics

Bakeout Control Unit BCU14

» Bakeout Control Unit BCU14

The BCU14 is the equipment for heating zones of the vacuum systems as well as heating samples inside the preparation chambers.

read more
See more  ›

» Manipulators

Z Slide

» Z Slide

The Z Slide is a precision, high rigidity UHV specimen translator having Z motion.

read more
See more  ›

» Software

Rapid Scientific Environment

» Rapid Scientific Environment

Rapid SE is rapid lab environment system builder for scientists offering many of useful features developed especially to meet most of experiment expectations.

read more
Recipe Editor

» Recipe Editor

Recipe Editor module is designed to perform technological process base on recipe. It give user possibility to create recurrent process.

read more
Chart 2D

» Chart 2D

Chart 2D module give user access to see graphic representation of data in time. User can select which data he want to see, also has possibility to configure axes.

read more
ION Source Control

» ION Source Control

ION Source Power Supply software extension for data acquisition and convenient control.

read more
Flood Source Control

» Flood Source Control

FLOOD Source Power Supply software extension for data acquisition and convenient control.

read more
X-Ray Source Control

» X-Ray Source Control

X-RAY Source Power Supply software extension for data acquisition and convenient control.

read more
UV Source Control

» UV Source Control

UV Source Power Supply software extension for data acquisition and convenient control.

read more
Electron Source Control

» Electron Source Control

ES Source Power Supply software extension for data acquisition and convenient control.

read more
Heating & Temperature Controller

» Heating & Temperature Controller

Heating & Temperature Controller software extension for data acquisition and convenient control.

read more
Multi-Gauge Control

» Multi-Gauge Control

Multi Gauge Controller software extension for data acquisition and convenient control.

read more
Electron Beam Evaporator Control

» Electron Beam Evaporator Control

Electron Beam Evaporator Controller software extension for data acquisition and convenient control.

read more
Residual Gas Analyzer

» Residual Gas Analyzer

The RGA module allows fully functional control of residual gas analyzers.

read more
Multiaxes Manipulator Control Application

» Multiaxes Manipulator Control Application

The Multi-Axis Control application has been designed for simple control of up to 6 motorized manipulator axes.

read more
Quartz Balance Control Application

» Quartz Balance Control Application

Measurement of frequency, rate and thickness from both channels simultaneously.

read more
Bakeout Control

» Bakeout Control

Full software control of bakeout time and temperature.

read more
PCU Control

» PCU Control

Full software control of a single vacuum/UHV system including pumps, valves and pressure gauge set.

read more
Heater Power Supply Control

» Heater Power Supply Control

Full software control of current and voltage.

read more
Titanium Sublimation Pump (TSP) Control

» Titanium Sublimation Pump (TSP) Control

Full software control of current, run time per filament, off time per filament, number of active filaments (up to four) and cycle count.

read more
Molecular Beam Epitaxy

» Molecular Beam Epitaxy

The MBE Control Module is our dedicated, easy to use software package for long term, stable control of MBE growth processes.

read more
Thermal Desorption Spectrometer

» Thermal Desorption Spectrometer

TDS Control Application allows precise control of Thermal Desorption Spectroscopy processes with fully integrated management of a temperature controller and mass spectrometer combination.

read more
Spectrium

» Spectrium

PREVAC acquisition and analyser control software.

read more

TOP

Important:
this site uses cookie files.

We use information saved in cookie files, among others, in statistical purposes and in order to fit the service to individual needs of the user. In your browser you can change your cookie files settings.

Using the site without changing cookie files settings means they will be saved in device memory. More information with tips how to change settings can be found in Privacy policy.

Close

Query list